coleman saluspa error codes

If E90 persists, check and ensure there is no debris inside the spa tub inlet and outlet grids. Please do feel free to ask in the comment section below. I have a question. Yes. Yes! The pump has a 5-minute auto-lock. We'll start with the easy ones first. If this is the case, sometimes a quick smack, not too hard, to the side of the pump will get the paddle to drop into the normal position. current price $25.37. Even small amounts will help. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times. IMPORTANT: Because of the combined weight of the SaluSpa, water, and users, it is extremely important that the base where the SaluSpa is installed is smooth, flat, level and capable of uniformly supporting the weight for the entire time the SaluSpa is installed (not on the carpet or other similar material). Another thing with the impeller can be a rusty or damaged magnet. Dont leave it unusedIf you leave your LayZSpa out in winter without using it, and the temperature drops below 4C, the water could freeze within the pump and cause serious damage. To lock or unlock the pump, place a finger over the lock/unlock button for 3 seconds. As with most products, Coleman spas most likely need troubleshooting at some point during their lifetime. In this case you will need to replace the impeller. Plug the GFCI into a power outlet, the indicator turns red. Coleman 4 Person 60 Jet Outdoor Inflatable Hot Tub. No obstructions or odd sounds from clogged lines/damage Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. "headline": "Spa Error Codes -The Big List", Pool chemicals are potentially toxic and should be handled with care. If you find any errors or just have questions, you can contact me here. However, they struggle to maintain the set water temperature if the weather drops below 40 degrees Fahrenheit. Spa may be partially deactivated or low speed pump (and air blower if equipped) may activate to lower temp. A faulty air pump usually causes this error code. I am not sure where to get the heater units for these, but if you let me know where you live I may be able to point you to someone that may know. The garage is the only room in your house that has (or can easily have) all of the above. Worked greatuntil a few weeks ago. 220-240v~50hz, 2,050w at 20c, ipx5 (12 pages), 20-240v~50hz, 2050w I also sell just the paddle separately. You might see few other error codes on your Coleman Lazy Spa control panel like lazy spa E08, lazy spa E03, And lazy spa E02. Woamkyn Coleman Spa 2 Inch Pump Repair Split Nut 2 Pack 106850. Reset power to the spa. It is best though to have the water above the outlet pipe. Related Price Pages:Coleman Air Conditioner Prices, Coleman Furnace Prices. "dateModified": "2022-04-28", Replacing the paddle fixed my problem for a while but once again, the E02 error is back. CONSULT YOUR PHYSICIAN FOR RECOMMENDATIONS. WARNING: Water attracts children; Always attach a spa cover after each use. Install at least 5 feet (1.5 m) from all metal surfaces. "height": "500", My writing style is engaging, informative, and entertaining. Believe it or not, your filters being dirty can actually cause this error. Your email address will not be published. The suction fittings in this spa are sized to match the specific water flow created by the pump. To use the chemical dispenser, please follow the below instruction. 2) ensure all the return jets are open and that your "T" handle valves are in the proper position for operation. They cant pull much water on their own. 1997-2000 Coleman Spas/ Cal Cooperage 100 Series Owners Manual. CODE: E1. "@type": "BlogPosting", No lie. When using this electrical equipment, basic safety precautions should always be followed, including the following: WARNING To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. Do not use spa. Sounds like just enough that once there is a minor flow issue with a dirty filter, it trips the flow sensor. Always check the air-valve carefully before use. I found pieces of a ~3/4 Dia O-ring in the float sensor and another in the pump impeller. NOTE: We recommend changing your filter cartridges every week or, if the filter cartridges remain soiled and discolored, they should be replaced. I can use my home automation in Home Assistant that I wrote for full control over the egg. To modify the timer settings: Press the button and use the or button to adjust. Press this button for 2 seconds to active the control panel bottons and the light turns to green. Coleman Salu spa e03 Code Error fixing If you have a Coleman Saluspa and are getting an e03 code error, dont worry. There are a few things that can cause this error code to occur, such as a clogged filter or a bad pump. Only plug it in when told to do so. Push that pin from the side being careful not to break it, and pull it out. To make any bubbles congregate in the center of the tube where you can see them, slightly raise. You should also clean the filter cartridges on a regular basis to keep your inflatable hot tub water clean. You should first check the spas filter to see if it needs to be replaced. If you need to clean or replace it, then do so. Putting a good bit of this solution in the descaler and turning the pump and heater on for 15 to 30 minutes will break up and disolve the limescale buildup and get you back running quickly. PROBLEM:Outdoor condenser pipe sensor error. This site will focus on Swimming, Pools, Home Spas, Saunas, Hot Tubs and any way you can think of to relax and unwind. NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 48 hours; Reservation time adjustment (the number of hours FROM NOW when the heater will begin to function) may be set from 0 to 99 hours. Does it flow out well? Add water to the spa. }, Required fields are marked *. After that, Try the flush with high(er) powered hose water. Heater is off, but other spa functions run normally. DO NOT STAY IN SPA FOR LONGER THAN 10 MINUTES. If you no longer have it, search online by using your model, and the year of your hot tub, followed by the word "manual" or "troubleshooting." }, Switch out the filters! Do not use spa. 0:00 / 0:58 Coleman SaluSpa Error 03 Easy Fix JoshDes 4 subscribers Subscribe 5.5K views 11 months ago My hot tub randomly shut off last night due to Error 02, which happens every now and. }. Ive got an externally pumped tub with better flow rate/heating an extra filter and its still controlled by the egg. Ive never gotten that far into the unit. With one hand, hold the backside of the air-valve from the inner side of the spa wall and turn the wrench clockwise. Coleman Salu spa e02 Code erroris triggered when the water level in the spa is too low. One of the main causes of this is broken plastic around the magnet that causes the magnet to get wet and rust. WHEN PREGNANT, SOAKING IN HOT WATER FOR LONG PERIODS CAN HARM YOUR FETUS. SN, Sn1, Sn2 Sn3, HL, E1, E3, Prh, HtS, Blinking Lights; Hi Limit Sensor Failure. Q. If you try to start your water pump with no water in the tub or with the water level below the filter inlets, you will get this error. I have measured voltage in the powersupply to the pump to 12v. NOTE: Damage resulting from chemical imbalance is not covered by the warranty. Remove the bottom panel from the egg by turning it over. PROBLEM:Inverter module IPM protection. Its then followed by the EO2 error. On the control panel, press the button that increases the water temperature. Simply cleaning the filter cartridge is not enough for proper maintenance, we recommend you use pool chemicals to maintain water chemistry and chlorine or bromine tablets (do not use granules) with the chemical dispenser. Coleman saluspa E03 code BRAND NEW UNIT reset did nothing Right out of box need is to work ASAP for son w/special needs. Some of these have the magnet encased in plastic like the one to the left, and some have the magnet exposed like the one shown above. Check if the short tube beneath the elbow connector (embedded inside the tub) is sufficiently improper. Before screwing on filters, submerge them until all air has been expelled. "wordCount": "1826", This error code indicates a problem with the pump, which needs to be replaced. I was able to get full automation control over the touch buttons. Do Not Sell or Share My Personal Information, Flow/pressure switch either open or closed, Water dangerously hot, electronic fault, system shut down. If it is, make sure the pump and heater are turned on. Good Luck! Say what now? . CODE:E8. If you still have concerns, questions, or doubts about any of these Coleman SaluSpa Setup and Lazy Spa E02 error code. What to do? Welcome To Our Website! You say that you replaced the water pump with a used one. Properly sanitized water keeps the units durability and makes it running last longer. This should clear the error code. Coleman Saluspa e02 Code: How To Error fixing. After 72 hours of filtration (without using the power saving timer function), the pump will hibernate and flash End with the current water temperature. Filters clean. b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to100F (38C). "name": "Leslie's, Inc.", If there is debris inside, unscrew the spa inlet/outlet grid with a screwdriver. 1. Related Repair Pages:Coleman Air Conditioner Repairs, Coleman Furnace Repairs. By creating an account you agree to the Hunker. To heat the water from cold can take24-48 hours. Is it to replace both the waterflow sensors? Broken, Stuck or Damaged Impeller or Impeller Shaft. Since you have cleaned the filter, try the following before replacing your flow sensor. Remove the access panel to ensure these are fully open. The product is once again ready for use. Temperature sensor fault, circuit open or faulty, Overtemp air temp around equipment is too hot, lack of air flow, Spa in standard mode; system message, not an error, Shown on startup, indicates temperature probe error, Shown on startup, indicates temperature is less than 39F, Time out error; contact manufacturer for support, Temperature set Celsius/Fahrenheit; system message, not an error. An insulating ground mat below the tub helps to maintain steady water temperature. The weight of the SaluSpa is approximately 300 pounds (136 kilograms). If you experience any problems with your spa, dont hesitate to contact customer service for assistance. The error happens with and without the filter installed. Please follow the Assembly instructions and drain the spa before inflating to the accurate pressure needed. DIY electronics, home automation and programming. i have the same E02 code once i plug the pump in the GFCI plug trips instantly. Reorient or relocate the receiving antenna. Another thing that you can try is resetting the pump. Test both, maybe the tube is twisted or obstructed or kinked inside the liner? Sign up for the Backyard Blast newsletter! 2 OTHER POSSIBLITIES Strike the pump firmly, but not violently Do not hit the pump on either the top or bottom Always ensure the stopper caps are removed from the inside of the liner before use FURTHER STEPS AND CO NTACT NUMBERS Plug-in the pump and start filling the air in the hot tub. When the pressure gauge reads above 1.2 it means the spa has fully inflated. Hello and first of all, we congratulate you on the purchase of your new Coleman Lazy Spa. All rights reserved. To drain Coleman Lay-Z-spa or know how to drain Coleman SalusSpa follow these steps: You might get the Lazy Spa E02 error code on the Coleman Slauspa. c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies. We use ours inside, clean and change the filter weekly/weekly, and whenever I put a new filter on it will run fine for a few days heating it, then when I go to get in, bam, The error code. Overheat; one sensor has detected 118F, spa has shut down. Enter code OUTSIDE in cart. In the steps outlined here, there are many causes that can be fixed without the need to replace parts. They do not look worn and almost as new and as mentioned i can measure when the magnets activate. PROBLEM:Compressor top overheating protection. A common brand is made by a company called Oust and is designed to clean coffee kettles, irons and dishwashers. Of course, that indicates a water flow issue with the pump not coming on I can only assume the pump is the problem? So the issue was with the thermometer inside of the pump reading closer to ambient air temps (20F) due to it not running overnight. It is recommended you store the spa in its original package in a warm dry place. If it runs and doesn't give you the E02 error, this is your problem. If you hold these buttons down the values will rapidly increase or decrease. Q. "mainEntityOfPage": "https://lesliespool.com/blog/spa-error-codes-the-big-list.html", Make sure that both of these are set at the correct levels. Rinse off all soap residue after cleaning and dry your spa thoroughly before using it again. PROBLEM:Evaporator coil temperature sensor error. If reconnecting the filter immediately causes the water to stop flowing (and you then experience E02), the filter is the only obstruction to the water flow. First name. The e03 error code is generally caused by either a defective control panel or the air pump itself. The e02 code error is a prevalent error that can occur with the Coleman Saluspa. NOTE: After setting, the screen flashes the current temperature and time alternately. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To re-activate the pump press lock/unlock button for 3 seconds. If this is the case, the paddle will need to be replaced. Slowly lift the cover off, but watch for the ribbon cable that is attached. I have heard of people that have put the wrong impellers in the pumps claiming that they just replaced the impeller, only to find that the one they put in was too small or something and the impeller could not spin properly. I did some further observations. To minimize these effects, it is best to provide plenty of ventilation to the selected area. Hence the need for aBIG LIST of CODES. Opened up and checked magnet flow disk. For support please visit us at: bestwaycorp.com/support, The best way to install your SaluSpa is to have it professionally installed by a licensed contractor. Freezing can severely damage the spa. "height": "500", This really helps out me and my site so thank you in advance! System disabled. Each company uses its own conventions for naming the various system faults. One reason could be that your liner is low on air. Remove any remaining water inside the spa using a wet/dry vac or a mop. If the error goes away, we know it's the filter. How do I remove the debris filter? Remove the four screws on the top of the sensor and lift the top off being careful of the sensor wire that is connected to it and the rubber o-ring seal under the lid. You may be able to just set the lid aside with the ribbon cable attached. This paddle is supposed to lift up and trigger a sensor to tell the system that water is moving when the pump is turned on. Add. Customer: Just found it like this tonight read more Patrick D. Senior Service Technician Bachelor of Arts 340 satisfied customers I am trying to set up a inflatable saluspa. The order in which we will cover the listed solutions is to cover the basics that don't require part replacements first to rule them out first. Feel free to leave us a message and we will be in touch as soon as an agent is available. Posted on Apr 15, 2018 1 Related Answer Anonymous Remember there is 2 1/2 feet of water pressure above that port so it should rush out really well. DANGER Risk of Electric Shock. 5: The side hose is too short, pulling a kink in the short hose behind the elbow connector, The e02 Code Error: what causes it and how to fix it, Section 2: Cleaning the inside of the Coleman Saluspa, Section 3: Replacing the Coleman Saluspas water filter, From Classic to Cutting Edge: Best Hot Tub Cover Lift Types, Dont Let the Heat Fool You: Hot Tub Benefits and Risks, The Most Affordable and Reliable Hot Tub Lifesmart plug and play, The Most Affordable and Spacious: Coleman Saluspa Havana Hot Tub, Hot Tub and Swin Spa Industry Energy Efficiency Standards APSP-14, Wooden Spa: A Simple, But Luxurious Tool for the Home, The Secret To The Best Hot Tub Temperature, How to Survive Using a Hot Tub in Winter Outside, The Best Submersible Pump for Hot Tub: Keep it Clean & Clear, Escape the Winter Chill: Best Hot Tub for Cold Climates, Unlock the Healing Powers of a Steam Room During Period, Protect Your Health: Is Low Alkalinity In Hot Tub Dangerous. Many of the impellers used in the egg have an impeller shaft that is made of ceramic. Im almost wondering if ive got a partially shorted power lead to the pump unit itself. "@type": "ImageObject", Then I disconnected the power lines going to the bus bar and the control board. Another option to solve this would be to get a short piece of rigid pipe to fit inside this pipe to keep it from collapsing. To do this, first, turn off the power to the spa. GFCI plug replaced, no change This is not true though, since the water temperature was actually around 70. If you see a bunch of junk in there, it is probably restricting the water flow enough to cause the error. But the pump is very useful to me. Replace the cover being sure to connect the ribbon cable if you had it disconnected. Simply hosing off the dirt and junk from the filters can restore the water flow to a normal level. When you push the filter button, do you hear the pump run for a couple seconds before getting the E02 error? c) Connect to a grounded, grounding type receptacle only. Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. You can also try cleaning the filter with a hose or vacuum cleaner. CODE:F2. Flush both ways (In the Out, and In the In ports). www.hottubpatio.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com. 2. This article will help you select the problem to get back to enjoying your hot tub. Here in this setup guide, I have laid out the Coleman SaluSpa Set up instructions in easy to follow 7 steps. Replace the filter cartridge and fill the spa with fresh water. Leaving the spa uncovered will increase the heating duration required. anemic to say the least. Using soapy water, cover the air-valve to check if air is leaking, if so, use the provided wrench to fasten the air-valve following these steps: Detergent residues and dissolved solids from bathing suits and chemicals may build up on the spa walls.

Herman Wedemeyer Cause Of Death, Articles C

coleman saluspa error codes

You can post first response comment.

coleman saluspa error codes